Quincy Compressor’s are built to last, and they require regularly scheduled maintenance. Consult each product’s Instruction Manual for model-specific requirements. General guidelines are listed below:
Every 40 hours (or weekly)
- Manually operate the pressure relief valves to be certain they are working.
- Clean the cooling surfaces of the intercooler, after cooler and compressor.
- Check the compressor for air leaks.
- Check the compressed air distribution system for leaks.
- Inspect lubricant for contamination and change if necessary
- Clean or replace the air intake filter. Check more often under humid or dirty conditions.
Every 160 hours (or monthly)
- Check belt tension
Every 1,000 hours (or every six months)
- Change lubricant and check/change filter(s). *40W ISA 150 non-detergent compressor lubricant
- Inspect fluid condition (change if needed) *Synthetic 30W ISO-68 non-detergent compressor lubricant.
- Re-torque the cylinder to head capscrews. Refer to instruction manual.
- Inspect compressor valves for leakage and/or carbon build-up. If excessive sludge build-up exists inside the crankcase, clean the inside crankcase and the screen. Always use a safety solvent and follow directions provided in the instruction manual.
Every 2,000 hours (or every 12 months)
- Inspect the pressure switch diaphragm and contacts. Inspect the contact points in the motor/starter.
- Change lubricant and check/change filter(s). *Synthetic 30W ISO-68 non-detergent compressor lubricant.