Quincy Maintenance

Quincy Compressor’s are built to last, and they require regularly scheduled maintenance. Consult each product’s Instruction Manual for model-specific requirements. General guidelines are listed below:

Every 40 hours (or weekly)

  • Manually operate the pressure relief valves to be certain they are working.
  • Clean the cooling surfaces of the intercooler, after cooler and compressor.
  • Check the compressor for air leaks.
  • Check the compressed air distribution system for leaks.
  • Inspect lubricant for contamination and change if necessary
  • Clean or replace the air intake filter. Check more often under humid or dirty conditions.

Every 160 hours (or monthly)

  • Check belt tension

Every 1,000 hours (or every six months)

  • Change lubricant and check/change filter(s). *40W ISA 150 non-detergent compressor lubricant
  • Inspect fluid condition (change if needed) *Synthetic 30W ISO-68 non-detergent compressor lubricant.
  • Re-torque the cylinder to head capscrews. Refer to instruction manual.
  • Inspect compressor valves for leakage and/or carbon build-up. If excessive sludge build-up exists inside the crankcase, clean the inside crankcase and the screen. Always use a safety solvent and follow directions provided in the instruction manual.

Every 2,000 hours (or every 12 months)

  • Inspect the pressure switch diaphragm and contacts. Inspect the contact points in the motor/starter.
  • Change lubricant and check/change filter(s). *Synthetic 30W ISO-68 non-detergent compressor lubricant.